PMS® Cleanroom Classification and Monitoring Services

PMS® Classification and Monitoring Services

 

 

*This service is offered only in the UK, Ireland, Switzerland, and Austria*

 

Cleanroom Certification and Monitoring

Particle Measuring Services provides a complete cleanroom certification service adhering to ISO and GMP industrial standards. All tests are carried out by trained, responsible, and flexible staff working to documented and approved test procedures. Cleanrooms certified/commissioned and validated to ISO 14644-1,14644-3, EU Guide, and IEST-RP-CC-006.3 practices.

Cleanroom Tests carried out:

  • HEPA filter leak test
  • Airborne particle count
  • Air change rates
  • Pressure profiles
  • Air velocity
  • Visualization
  • Revoveriew
  • Temp/Humidity
  • Light levels
  • Noise levels

 

Airflow VisualizationUnidirectional Airflow Devices (LAFs)

Unidirectional airflow devices certified/commissioned and validated to IEST-RP-CC-002 2.#U Guide and ISO 14644-1

Cleanroom Tests carried out:

  • HEPA filter leak test
  • Airborne particle count
  • Velocity
  • Pressure
  • Visualization
  • Temp/Humidity
  • Light Levels
  • Noise Levels

 

Microbiological Safety Devices

Microbiological Safety devices certified/commissioned and validated to EN 12469

Cleanroom Tests carried out:

  • HEPA filter leak test
  • Airborne particle count
  • Velocity
  • Pressure
  • KiDiscus
  • Visualization
  • Temp/Humidity
  • Light Levels
  • Noise Levels

 

Isolators

Isolators certified/commissioned and validated to IEST-RP·CC·006.3, ISO14644-1 and EU Guide

Cleanroom Tests carried out:

  • HEPA filter leak test
  • Airborne particle count
  • Velocity
  • Pressure
  • Visualization
  • Temp/Humidity
  • Light Levels
  • Noise Levels

 

Fume Hoods

Fume Hoods certified/commissioned and validated to EN 1417S

Cleanroom Tests carried out:

  • Inward Velocity
  • Airborne particle count
  • Visualization
  • Alarm Verification

 

Operating Theaters

Operating Theaters certified/commissioned and validated to IEST-RP·CC·002.2, ISO14644-1 and EU Guide

Cleanroom Tests carried out:

  • HEPA filter leak test
  • Airborne particle count
  • Velocity
  • Visualization
  • Temp/Humidity
  • Light Levels
  • Noise Levels

 

Compressed Air/Nitrogen

Cleanroom Tests carried out:

  • HEPA filter leak test
  • Airborne particle count
  • Air change rates
  • Pressure profiles
  • Visualization
  • Temp/Humidity
  • Velocities
  • Recoveries

 

All Cleanroom Monitoring tests carried out by trained, responsible, competent and flexible staff working to documented test procedures.

  • ISO 14644-1
  • EU GUIDE to GMP
  • ANNEX 1
  • ISO 14644-3
  • IEST0RP-CC006.3
  • EN12469
  • IEST0RP-CC002.2
  • IEST0RP-CC034.2
  • EN 141755