• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

+65 6496 0330

  • Youtube
  • Linkedin
  • Singapore
    • 中文
    • 台灣
    • Denmark
    • English
    • English / CH
    • Français
    • Français / CH
    • Deutsch
    • Deutsch / CH
    • Deutsch / AT
    • Italiano
    • 日本語
    • 한국어
    • Português
    • Español
Newsletter

Search

  • Linkedin
  • Twitter
Particle Measuring Systems
Without measurement there is no control
Get a Quote
  • Home
  • Products
    • Aerosol Particle Counters
    • Liquid Particle Counters
    • Microbial Samplers
      • BioCapt®Certificates of Analysis
    • Compressed Gases Particle Counters
    • Molecular Monitors
    • Environmental Monitoring Systems
  • Education
    • Knowledge Center
      • Application Notes
      • Videos
      • Webinars – Archived
    • Particle College
    • Software / Data Management
    • Blog
  • APPLICATIONS
    • INDUSTRIES
      • PHARMACEUTICAL
      • SEMICONDUCTOR
      • PHOTONICS&OPTICS
      • AEROSPACE
      • Cosmetics & Personal Care
    • Annex 1
    • ISO 14644
    • 21 CFR 11
    • ISO 21501-4
    • USP 788
    • USP 797
    • PARTS CLEANLINESS TESTING
  • Service and Support
    • Advisory Service
    • Product Calibration and Service
    • Customer Service
  • About Us
    • Contact Us
    • Why PMS
    • Particle Measuring Systems’ Executive Team
    • Particle Measuring Systems’ Careers
    • Corporate Responsibility
    • COBE
    • Parent Company
    • Press Releases
    • Credibility & Registrations
    • Trademarks & Patents
News Blog
May 19, 2020 04:27 PM

Microbiological Plate Incubation and Pharmaceutical Risk Assessment

Written by Teresa Riccioni

The new EU GMP Annex 1 draft, Rev 12 specifies the requirements of a pharmaceutical risk assessment to set appropriate microbiological plate conditions. This blog discusses this requirements to use a risk assessment, and then provides an interpretation on how to apply it and use it in different stages of the manufacturing process.

There are three main concepts regarding this:

  1. “Quality Risk Management” applies to all of Annex 1 and is the underlying concept for understanding and interpreting Annex 1.
  2. A relevant Pharmaceutical Risk Assessment is expected for each area.
  3. Companies are expected to implement a Quality Assurance system to fulfill the quality objectives associated with various areas of interest

Section 9 of Annex 1 says that a Risk Assessment should be used to establish a comprehensive environmental monitoring program, including:

  • sampling locations
  • sampling frequency
  • method used
  • incubation conditions

A pharmaceutical Risk Assessment should be based on knowledge of:

  • historical monitoring data
  • monitoring data obtained during qualification
  • knowledge of typical microbial flora isolated from the environment

The result of the Risk Assessment is to establish the most appropriate incubation conditions to identify all potential microorganisms associated with an environment. That is, the goal is to demonstrate that your methods have considered all risks for maximum recovery of microorganisms. This is particularly important in Grade A and B Cleanrooms where the counts are generally very low, and the environmental conditions do not favor microbiological detection.

Next steps

  1. Establish the most appropriate incubation conditions to identify all potential microorganisms associated with your environment
  2. Take information from USP and EU Pharmacopeia
  3. Risk Assessment: Evaluate the environment and process/product
  4. Risk Assessment: Review data regularly to confirm the effectiveness of the conditions

Pharmaceutical Risk Assessment per Annex 1 for Microbial Plate Incubation

A Pharmaceutical Risk Assessment should be holistic and evaluate the characteristics of the process, products, facilities and environmental conditions that favor the growth of:

  • anaerobic microorganisms
  • slow-growing microorganisms
  • yeasts and molds

There are differences in performing a Risk Assessment in existing or new departments. For example, in existing departments, there is historical data would should be considered. In a new department with no historical information, you must define the incubation condition based on a scientific-based approach:
Pharmaceutical Risk Assessment for new v. existing departments

Ready to get started?!

Particle Measuring Systems has a contamination control advisory team that can provide you with sterility assurance audits to prepare you for the review of the regulatory agencies or to identify the areas where to improve. Get a Risk Assessment
BioCapt® Single-Use Microbial Impactor

cleanroom microbiology and Single Use TechnologyThe BioCapt® Single-Use Microbial Impactor from Particle Measuring Systems eliminates the risk of false positive results and final product contamination from microbial sampling interactions, while decreasing the cost of investigations. The single use sampling head enables manufacturers to monitor their full process, eliminating the risk of non-conclusive qualitative results from settle plates.

The innovative design combines a media plate and sampling head into a single unit. This unique solution eliminates the handling risk, costs, and complications related to autoclaving and stainless-steel head disinfection

BioCapt Single Use Microbial Impactor

Visit our Annex 1 page or read more of our Annex 1 blogs:

  • Cleanroom Classification, Cleanroom Monitoring, Cleanroom Qualification per Annex 1
  • Cleanroom Process Risk Assessment per Annex 1
  • Cleanroom Sampling Points
  • Viable Non Viable Particle Counts
  • Contamination Control Strategy
  • Quality Risk Management
  • Cleaning & Disinfecting a Cleanroom per Annex 1
  • Cleanroom Single Use Requirements per Annex 1

Filed Under: Particle Knowledge

Archives

  • January 2021 (1)
  • December 2020 (2)
  • November 2020 (5)
  • September 2020 (4)
  • August 2020 (1)
  • July 2020 (3)
  • June 2020 (3)
  • May 2020 (6)
  • April 2020 (11)
  • March 2020 (2)
  • February 2020 (4)
  • January 2020 (1)
  • December 2019 (2)
  • November 2019 (3)
  • May 2016 (1)
  • March 2016 (1)
  • February 2016 (3)

Subscribe to our news feed!

Products

  • Aerosol Particle Counters
  • Liquid Particle Counters
  • Microbial Samplers
  • BioCapt®Certificates of Analysis
  • Compressed Gases Particle Counters
  • Molecular Monitors
  • Software / Data Management

Industries

  • Pharma
  • Semi
  • Photonics & Optics
  • Aerospace
  • Industrial Manufacturing

Service & Support

  • Advisory Service
  • Product Calibration and Service
  • Customer Service

Knowledge Center

  • Application Notes
  • Particle College
  • Videos
  • Blog

About Us

  • Contact Us
  • Why PMS
  • Particle Measuring Systems’ Executive Team
  • Particle Measuring Systems’ Careers
  • Corporate Responsibility
  • COBE
  • Parent Company
  • Press Releases
  • Credibility & Registrations
  • Trademarks & Patents

Particle Measuring Systems- USA

Corporate Headquarters
5475 Airport Blvd
Boulder, CO 80301

T. +1-303-443-7100
T. +1-800-238-1801
F. +1-303-449-6870
E. [email protected]

Keep in touch! Receive industry news from us:

Products

  • Aerosol Particle Counters
  • Liquid Particle Counters
  • Microbial Samplers
  • BioCapt®Certificates of Analysis
  • Compressed Gases Particle Counters
  • Molecular Monitors
  • Software / Data Management

Industries

  • Pharma
  • Semi
  • Photonics & Optics
  • Aerospace
  • Industrial Manufacturing

Applications

  • ISO 21501-4
  • Parts Cleanliness Testing

Service & Support

  • Advisory Service
  • Product Calibration and Service
  • Customer Service

Education and Training

  • Knowledge Center
  • Particle College
  • Software / Data Management
  • Blog

About Us

  • Contact Us
  • Why PMS
  • Particle Measuring Systems’ Executive Team
  • Particle Measuring Systems’ Careers
  • Corporate Responsibility
  • COBE
  • Parent Company
  • Press Releases
  • Credibility & Registrations
  • Trademarks & Patents

Particle Measuring Systems- SG

Corporate Headquarters
5475 Airport Blvd
Boulder, CO 80301

T. +1-303-443-7100
T. +1-800-238-1801
F. +1-303-449-6870
E. [email protected]

Keep in touch! Receive industry news from us:

  • Privacy Policy
  • Legal

© Copyright 2021 - Particle Measuring Systems is a Spectris company