• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

+45 7070 2855

  • Youtube
  • Twitter
  • Linkedin
  • Denmark
    • 中文
    • 台灣
    • Singapore
    • English
    • English / CH
    • Français
    • Français / CH
    • Deutsch
    • Deutsch / CH
    • Deutsch / AT
    • Italiano
    • 日本語
    • 한국어
    • Português
    • Español
Newsletter

Search

Particle Measuring Systems
Without measurement there is no control
Get a Quote
  • Home
  • Contamination Monitors
    • Aerosol Particle Counters
    • Liquid Particle Counters
    • Microbial Samplers
    • Compressed Gas Contamination Monitoring
    • Molecular Monitors
    • Software / Data Management
  • Education
    • Live Q&A Event – Scandinavia
    • PMS™ Knowledge Center
      • Application Notes
      • Beginner Guide to Particle Counting
      • Videos
      • PMS™ Webinars
    • Contamination Monitoring Blog
  • Applications
    • PRO Series for Complete Contamination Control
    • Industries
      • Pharma
      • Semi
      • Photonics & Optics
      • Aerospace
      • Isolator & Controlled System Manufacturers
      • ISO 22716 Solutions for Cosmetics & Personal Care
    • USP 797
    • USP 788
    • ISO 21501-4
    • Annex 1 Latest Draft Revision Updates
  • Service and Support
    • Product Calibration and Service
    • FMS/EMS Project Management Services
    • Customer Service
    • Advisory Service
    • Hardware & Software Support Solutions Center
  • About Us
    • Contact Us
    • Why PMS
    • Executives
    • Particle Measuring Systems’ Careers
    • Corporate Responsibility, Sustainability, Health & Safety
    • COBE
    • Parent Company
    • Press Releases
    • Credibility & Registrations
    • Trademarks & Patents
Paper: Particle Counting Data Analysis

Understanding Particle Contamination in Chemical Distribution Systems

Advanced Data Analysis Strategies

particle counting in a chemical distribution systemAdvanced data analysis techniques can be implemented to quantitatively assess particle contamination data in state-of-the-art chemical distribution systems. Through examining the distribution of the rate of particle detection compared to Poisson’s distribution, it is possible to determine if particle variations are random or systematic and allow for the focus of improvement efforts to reduce particle levels with time. By analyzing the particle contamination data in the frequency domain via Fourier transform analyses, periodic cycles of contamination can be identified with the goal of associating contamination events with activities within the chemical delivery system.

Nanoparticle contamination is assessed based on the statistical distribution of the particle measurement rate. The statistical distribution of the rate of particle measurement will approach a Poisson distribution for fluids without systematic contamination sources. The deviation from Poisson statistics can be used as a figure of merit to quantify the stability of nanoparticle contamination in high purity chemical systems.

Fast Fourier Transform (FFT) algorithms can transform nanoparticle contamination data over time into its frequency components. This allows for the identification of cyclic, systematic contamination sources in the distribution system and is most usefully employed when the rate of particle detection deviates significantly from Poissonian statistics.

Read this paper to learn more about:

  • Quantitative mathematical methods of particle data analysis
  • Experimental approach to nanoparticle contamination detection using the Chem 20™ Chemical Particle Counter and Ultra DI® 20 Liquid Particle Counter
  • Deviation from Poisson (DFP) for a chemical distribution system

Complete the form to access the full paper

Relevant Blogs

20 nm Chemical Batch Sampling Solution with the SLS-20 Syringe Sampler

Effective Batch Sampling Down to 20 nm with the SLS-20 Batch Sampler

Chemical Batch Sampling to 20 nm with the SLS-20

Chemical Particle Counting to 20 nm with the SLS-20 Batch Sampler

Relevant Webinars

Monitoring Guidelines for the Control of Particle Contamination in High-Purity Process Chemicals

Relevant Papers

20 nm Chemical Batch Sampling Solution with the SLS-20 Syringe Sampler

Advanced Data Analysis Strategies for Understanding Particle Contamination in Chemical Distribution Systems

Monitoring Particles in Process Chemicals

Uncovering chemical quality improvements through a holistic approach to chemical quality management

Component Cleanliness Testing for Liquid Systems

Products

  • Aerosol Particle Counters
  • Liquid Particle Counters
  • Microbial Samplers
  • Compressed Gases Particle Counters
  • Molecular Monitors
  • Software / Data Management

Industries

  • Pharma
  • Semi
  • Photonics & Optics
  • Aerospace
  • Industrial Manufacturing

Service & Support

  • Advisory Service
  • Product Calibration and Service
  • Customer Service

Knowledge Center

  • Application Notes
  • Videos
  • Contamination Monitoring Blog

About Us

  • Contact Us
  • Why PMS
  • Executives
  • Particle Measuring Systems’ Careers
  • Corporate Responsibility, Sustainability, Health & Safety
  • COBE
  • Parent Company
  • Press Releases
  • Credibility & Registrations
  • Trademarks & Patents

Particle Measuring Systems- DK

Particle Measuring Systems Nordic
Korskildelund 4-6
2670 Greve, Denmark

T. +45 7070 2855
[email protected]

Keep in touch! Receive industry news from us:

Products

  • Aerosol Particle Counters
  • Liquid Particle Counters
  • Microbial Samplers
  • Compressed Gases Particle Counters
  • Molecular Monitors
  • Software / Data Management

Industries

  • Pharma
  • Semi
  • Photonics & Optics
  • Aerospace
  • Industrial Manufacturing

Applications

  • ISO 21501-4
  • Parts Cleanliness Testing
  • Annex 1 Latest Draft Revision Updates

Service & Support

  • Advisory Service
  • Product Calibration and Service
  • Customer Service

Education and Training

  • PMS™ Knowledge Center
  • Software / Data Management
  • Contamination Monitoring Blog

About Us

  • Contact Us
  • Why PMS
  • Executives
  • Particle Measuring Systems’ Careers
  • Corporate Responsibility, Sustainability, Health & Safety
  • COBE
  • Parent Company
  • Press Releases
  • Credibility & Registrations
  • Trademarks & Patents

Particle Measuring Systems- DK

Particle Measuring Systems Nordic
Korskildelund 4-6
2670 Greve, Denmark

T. +45 7070 2855
[email protected]

Keep in touch! Receive industry news from us:

  • Privacy Policy
  • Legal

© Copyright 2022 - Particle Measuring Systems is a Spectris company