• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

+39 06 9053 0130

  • Youtube
  • Twitter
  • Linkedin
  • Italiano
    • 中文
    • 台灣
    • Singapore
    • Denmark
    • English
    • English / CH
    • Français
    • Français / CH
    • Deutsch
    • Deutsch / CH
    • Deutsch / AT
    • 日本語
    • 한국어
    • Português
    • Español
Newsletter

Search

Particle Measuring Systems
Without measurement there is no control
Richiedi un preventivo
  • Home
  • Prodotti
    • Contatori di Particelle per Aria
    • Contatori di Particelle per Liquidi
    • Campionatori Microbiologici
      • BioCapt®Certificates of Analysis
    • Monitoraggio della Contaminazione nei Gas Compressi
    • Monitoraggio Molecolare
    • Software / Data Management
  • Formazione
    • Virtual Particle Days 2020
    • Knowledge Center
      • Application Notes
      • Guida Base al Conteggio Particellare
      • Video
      • Webinar – Archivio
    • Servizi di Training e Consulenza
    • Blog
  • Applicazioni
    • Industrie
      • Life Sciences/Farmaceutico
      • Semiconduttori
      • Fotonica e Ottica
      • Aerospaziale e Difesa
      • ISO 22716 Soluzioni per la Cosmetica e l’Igiene Personale
    • ISO 14644
    • ISO 21501-4
    • USP 788
    • USP 797
    • Annex 1 Ultimi Aggiornamenti
    • 21CFR 11
  • Servizi e Supporto
    • Servizi di Project Management del Sistema di Monitoraggio
    • Servizi di GMP
      • Misurazione
      • Smoke Test
      • Convalide Termiche
    • Servizio Calibrazione e Riparazione
    • Servizio Clienti
    • Servizi di Advisory
  • Chi siamo
    • Contattaci
    • Perché PMS
    • Management
    • Lavora con noi
    • Responsabilità Aziendale
    • COBE
    • Casa Madre
    • Comunicati Stampa
    • Qualità e Riconoscimenti
    • Marchi e Brevetti
Application notes

Efficienza di Campionamento Microbiologico secondo Feller

Efficienza in base al design dell’impattore microbiologico BioCapt®

Con quale efficienza raccogliete le particelle vitali (unità formanti colonie, CFU) sulle superfici dei supporti? I calcoli statistici che utilizzano la formula di Feller dimostrano che il design dell’impattore microbiologico BioCapt® migliora le efficienze di raccolta biologica nel campionamento dell’aria per il controllo microbiologico. Grazie alle scanalature di precisione che assicurano il flusso laminare, l’impattore sfrutta al massimo le efficienze di raccolta biologica per le particelle vitali conformemente a ISO 14698-1/Appendice B per il campionamento dell’aria ai fini del controllo biologico in camere bianche e ambienti controllati associati.

La presente nota applicativa consente di:

Table of statistical corrections according to Feller

  • Comprendere i risultati statistici calcolati mediante la formula di Feller.
  • Risolvere problemi derivanti dalle camere bianche e dagli ambienti controllati associati per le particelle vitali durante il campionamento di contaminanti microbiologici dell’aria.
  • Comprendere in che modo il design dell’impattore microbiologico BioCapt consente di migliorare le efficienze biologiche nei flussi d’aria laminari di 25–50 l/min e 100 l/min.

Su questo argomento sono disponibili maggiori informazioni. Compilate il modulo sul lato destro di questa pagina per ricevere una copia gratuita della nota applicativa Table of statistical corrections according to Feller for the BioCapt Microbial Impactor in microbial air sampling application note (Tabella di correzioni statistiche secondo Feller per l’impattore microbiologico BioCapt relativa al campionamento dell’aria per controllo microbiologico).

Abstract

The “Table of statistical corrections according to Feller for the BioCapt®Microbial Impactor in microbial air sampling” is based on the principle that, as the number of viable particles — colony forming units (CFUs) — impact on an agar plate increases, the probability that viable particles will enter unoccupied space decreases. In this application note, the values within the table are shown at flow rates of 25–50 L/min and 100 L/min. BioCapt Microbial Impactors are used on all Particle Measuring Systems microbial instruments, including the MiniCapt® Mobile Microbial Air Sampler and the MiniCapt® Remote Microbial Air Sampler. The BioCapt Single-Use has the same pattern of the BioCapt Microbial Impactor and therefore, the Feller’s table is applicable to this unique BioCapt Single-Use Impactor for 25-50 L/min flow rates.The Impactor’s design enables the capture of microbiologically viable particles on a suitable media surface for incubation and enumeration. These values represent calculated statistical results made using Feller’s formula (Feller, 1950).

Prodotti

  • Contatori di Particelle per Aria
  • Contatori di Particelle per Liquidi
  • Campionatori Microbiologici
  • BioCapt®Certificates of Analysis
  • Contatori di Particelle per Gas Compressi
  • Monitoraggio Molecolare
  • Software / Data Management

Industrie

  • Life Sciences/Farmaceutico
  • Semiconduttori
  • Fotonica e Ottica
  • Aerospaziale e Difesa
  • Produzione Industriale

Servizi e Supporto

  • Servizi di Advisory
  • Servizi di Misurazione GMP
  • Servizio Calibrazione e Riparazione
  • Smoke Test GMP
  • Servizi di Convalide Termiche GMP
  • Servizio Clienti

Knowledge Center

  • Application Notes
  • Video
  • Blog

CHI SIAMO

  • Contattaci
  • Perché PMS
  • Management
  • Lavora con noi
  • Responsabilità Aziendale
  • COBE
  • Casa Madre
  • Comunicati Stampa
  • Qualità e Riconoscimenti
  • Marchi e Brevetti

Particle Measuring Systems- IT

Particle Measuring Systems Srl
Via di Grotte Portella, 34
00044 Frascati (Roma)

T. +39-06-90530130
F. +39-06-9051315
[email protected]
P.I. 10427421002

Ricevi i nostri aggiornamenti:

Prodotti

  • Contatori di Particelle per Aria
  • Contatori di Particelle per Liquidi
  • Campionatori Microbiologici
  • BioCapt®Certificates of Analysis
  • Contatori di Particelle per Gas Compressi
  • Monitoraggio Molecolare
  • Software / Data Management

Industrie

  • Life Sciences/Farmaceutico
  • Semiconduttori
  • Fotonica e Ottica
  • Aerospaziale e Difesa
  • Produzione Industriale

Applicazioni

  • ISO 14644
  • ISO 21501-4
  • USP 797
  • Annex 1 Ultimi Aggiornamenti
  • 21CFR 11

Servizi e Supporto

  • Servizi di Advisory
  • Servizi di Misurazione GMP
  • Servizio Calibrazione e Riparazione
  • Smoke Test GMP
  • Servizi di Convalide Termiche GMP
  • Servizio Clienti

Formazione

  • Knowledge Center
    • Particle Days 2019
  • Servizi di Training e Consulenza
  • Blog

CHI SIAMO

  • Contattaci
  • Perché PMS
  • Management
  • Lavora con noi
  • Responsabilità Aziendale
  • COBE
  • Casa Madre
  • Comunicati Stampa
  • Qualità e Riconoscimenti
  • Marchi e Brevetti

Particle Measuring Systems- IT

Particle Measuring Systems Srl
Via di Grotte Portella, 34
00044 Frascati (Roma)

T. +39-06-90530130
F. +39-06-9051315
[email protected]
P.I. 10427421002

Ricevi i nostri aggiornamenti:

  • Privacy Policy
  • Note Legali
  • Marchi e brevetti
  • Accreditamenti e riconoscimenti

© Copyright 2021 - Particle Measuring Systems è una società del gruppo Spectris