• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

+1-303-443-7100

  • Youtube
  • Twitter
  • Linkedin
  • English
    • 中文
    • 台灣
    • Singapore
    • Denmark
    • English / CH
    • Français
    • Français / CH
    • Deutsch
    • Deutsch / CH
    • Deutsch / AT
    • Italiano
    • 日本語
    • 한국어
    • Português
    • Español
Newsletter

Search

Particle Measuring Systems
Without measurement there is no control
Get a Quote
  • Home
  • Particle Counters
    • Airborne Particle Counters
    • Liquid Particle Counters
    • Microbial Samplers
    • Compressed Gas Particle Counters
    • Molecular Monitors
    • Environmental Monitoring Systems
  • Education
    • PMS™ Knowledge Center
      • Papers
      • Webinars
      • Videos
      • Podcasts
      • Beginner Guide
      • Manuals
    • Particle College
    • Training Services
    • Blog
    • BioCapt® Certificates of Analysis (CofA)
  • Applications
    • Industries
      • Pharmaceutical
      • Semiconductor
      • Aerospace
      • Cosmetics & Personal Care
      • Isolator & Controlled Systems
      • Food & Beverage Safety
      • Photonics & Optics
    • Compliance
      • 21 CFR Part 11
      • Annex 1
      • ISO 14644
      • ISO 21501-4
      • USP 788
      • USP 797
    • Life Sciences Applications
      • Continuous Viable Monitoring
      • Pro Series
    • High Tech Applications
      • Industry Leading Sensitivity
  • Services and Support
    • Product Calibration & Service
    • FMS/EMS Project Management
    • Contamination Control Advisors
    • Hardware & Software Support
    • Customer Service
  • About PMS
    • Contact Us
    • Careers
    • About Us
    • Executive Team
    • Corporate Responsibility, Sustainability, Health & Safety
    • COBE
    • Why Choose PMS
    • Parent Company
    • Press Releases
    • ISO Registrations & Quality Policy
    • Trademarks & Patents
    • Anti-Slavery
    • Export Compliance
News Blog
November 15, 2017 03:00 PM

Series: Comparing Particle Loss in Transport Tubing for Instruments with Different Flow Rates

Written by PMS

Testing to Demonstrate Losses in 2-Meter-Long Tubing
Figure-2.pngEach of the above flow rate instruments was tested against a reference Lasair III 5100 particle counter. This reference unit has the highest volume and flow rate and therefore improves statistical significance due to the number of particles measured in a single sample period. Prior to testing, all Lasair III’s were calibrated in accordance to the ISO 21501-4 standard for the calibration of aerosol particle counters6. This base-lined all particle counters such that no significant instrument-to-instrument error existed.

The reference unit was placed directly beneath the outlet of the HEPA filtered air supply and had no sample tubing attached (Figure 2). Each of the units under test: Lasair III 310C, Lasair III 350L and the Lasair III 5100, had 2 meters (2 m) of tubing attached and the inlet of this tubing was located adjacent to the reference unit input. This minimized any sample errors and ensured that the same number of particles was delivered to each transport mechanism, tubing, or directly to the sample inlet.

To minimize the particle sizing error, only NIST traceable PSL (Polystyrene Latex Spheres) and DRI-CAL particle size standards were used. Three particles were chosen for testing: 0.5 µm and 5.0 µm. The size standard aerosol mist was generated using the PMS PG-100 Particle Generator, which nebulizes and dries the particles prior to delivery into the HEPA filtered air flow and supplies the particles to the test instruments. The larger 5.0 µm DRI-CAL particles were generated using the PMS Large Particle Generator, which uses shear forces to deliver individual particles to the test instruments, also via the HEPA filtered air.
The 2 m sample tubing selected was Excelon Bev-A-Line® XX. Bev-A-Line tubing is preferred as it is semi-rigid tubing, thus minimizing the risk of kinks in the tubing, and the inner surface is lined with a HYTREL® polymer that offers a very low friction surface suitable for the transportation of particles.

The next installment will discuss the results of testing and their conclusions. To download the full paper, click here.

Filed Under: Particle Knowledge

Archives

  • May 2022 (2)
  • April 2022 (2)
  • December 2021 (2)
  • November 2021 (6)
  • October 2021 (5)
  • September 2021 (4)
  • August 2021 (5)
  • July 2021 (5)
  • June 2021 (12)
  • May 2021 (5)
  • April 2021 (6)
  • March 2021 (7)
  • February 2021 (6)
  • January 2021 (5)
  • December 2020 (3)
  • November 2020 (7)
  • September 2020 (4)
  • August 2020 (1)
  • July 2020 (3)
  • June 2020 (3)
  • May 2020 (6)
  • April 2020 (13)
  • March 2020 (2)
  • February 2020 (5)
  • January 2020 (2)
  • December 2019 (2)
  • November 2019 (4)
  • October 2019 (6)
  • September 2019 (3)
  • August 2019 (3)
  • July 2019 (2)
  • June 2019 (1)
  • May 2019 (4)
  • April 2019 (1)
  • March 2019 (3)
  • February 2019 (2)
  • January 2019 (2)
  • September 2018 (1)
  • July 2018 (4)
  • June 2018 (1)
  • April 2018 (2)
  • March 2018 (2)
  • February 2018 (1)
  • January 2018 (1)
  • November 2017 (11)
  • October 2017 (9)
  • September 2017 (9)
  • August 2017 (1)
  • March 2017 (1)
  • January 2017 (1)
  • November 2016 (1)
  • August 2016 (1)
  • May 2016 (1)
  • March 2016 (2)
  • February 2016 (9)
  • January 2016 (1)
  • July 2015 (1)
  • June 2015 (3)

Products

  • Aerosol Particle Counters
  • Liquid Particle Counters
  • Microbial Samplers
  • BioCapt® Certificate of Analysis (CofA)
  • Compressed Gas Particle Counters
  • Molecular Monitors
  • Software / Data Management

Industries

  • Pharma
  • Semi
  • Photonics & Optics
  • Aerospace
  • Particle Measurement for Industrial Manufacturing

Service & Support

  • Advisory Service
  • Product Calibration and Service
  • Customer Service

Knowledge Center

  • Particle Counting Education
  • Particle College – Electronics Industry Focused
  • Contamination Monitoring Videos
  • Blog

About Us

  • Contact Particle Measuring Systems
  • Why Choose Particle Measuring Systems
  • Particle Measuring Systems’ Executive Team
  • Careers
  • Corporate Responsibility, Sustainability, Health & Safety
  • COBE
  • Parent Company
  • Press Releases
  • ISO Registrations & Quality Policy
  • Trademarks & Patents
  • Anti-Slavery
  • Export Compliance

Particle Measuring Systems- USA

Corporate Headquarters
5475 Airport Blvd.
Boulder, CO 80301

T. +1 303-443-7100
F. +1 303-440-1090
E. [email protected]

Keep in touch! Receive industry news from us:

Products

  • Aerosol Particle Counters
  • Liquid Particle Counters
  • Microbial Samplers
  • BioCapt® Certificate of Analysis (CofA)
  • Compressed Gas Particle Counters
  • Molecular Monitors
  • Software / Data Management

Industries

  • Pharma
  • Semi
  • Photonics & Optics
  • Aerospace
  • Particle Measurement for Industrial Manufacturing

Applications

  • ISO 14644
  • ISO 21501-4
  • USP 797
  • Meet USP<788> Particulate Matter in Injections
  • Parts Cleanliness Testing
  • Annex 1 Latest Draft Revision Updates
  • 21CFR 11

Service & Support

  • Advisory Service
  • Product Calibration and Service
  • Customer Service

Education and Training

  • PMS™ Knowledge Center
  • Particle College – Electronics Industry Focused
  • Software / Data Management
  • Blog

About Us

  • Contact Particle Measuring Systems
  • Why Choose Particle Measuring Systems
  • Particle Measuring Systems’ Executive Team
  • Careers
  • Corporate Responsibility, Sustainability, Health & Safety
  • COBE
  • Parent Company
  • Press Releases
  • ISO Registrations & Quality Policy
  • Trademarks & Patents
  • Anti-Slavery
  • Export Compliance

Particle Measuring Systems- USA

Corporate Headquarters
5475 Airport Blvd.
Boulder, CO 80301

T. +1 303-443-7100
F. +1 303-440-1090
E. [email protected]

Keep in touch! Receive industry news from us:

  • Website Disclaimer
  • Third Party Privacy Notice
  • Privacy Policy
  • Legal

© Copyright 2022 - Particle Measuring Systems is a Spectris company