Facility and Pharmaceutical Net to Ethernet Instrument Traffic Notes (31.8 KB)
Consulte o download de arquivos acima para obter figuras e tabelas completas.
A versão HTML abaixo oferece uma rápida visão geral. Consulte o download de arquivos PDF.
General Notes
The PMS Ethernet protocol utilizes defaults that are assumed on the receiving side of the connection. This means that default values need not be sent which makes the packets vary in size depending on the contents. An example of this is would be a data message where no actual count data is transmitted if the counts are zero. Multiple PMS Ethernet messages can be sent in one packet. Instruments like the ENODE®, Lasair® II, and IsoAir® PLUS can queue data which will be transmitted when Facility or Pharmaceutical Net reconnects to the instrument.
Configuration Notes
Initial instrument configuration is normally performed once. The mechanism used is UDP/IP. This can be executed via either Multicast or Unicast. The instrument modification processing will request a configuration UDP/IP Unicast but set the new information via the TCP/IP connection when completed.
Initialization
Instrument initialization can occur when the application is first started or anytime the instrument is reconfigured. Reconfiguration can occur during runtime. Some instruments are reset prior to reconfiguration.
Packet from Facility and Pharmaceutical Net
Messages: Date/Time, Set Configuration, Get Configuration, Get Status Length: Approx. 163 bytes (To ENODE this could be 2K)
Packet from Airnet® Messages: Configuration Length: Approx. 300 bytes (From ENODE this could be 2K)
Packet from Airnet/ENODE Messages: Status Length: Approx. 115 bytes
Packet from Facility and Pharmaceutical Net Messages: Start Command, Get Status Length: Approx. 88 bytes
Packet from Airnet/ENODE Messages: Status Length: Approx. 115 bytes
Packet from Facility and Pharmaceutical Net Messages: Set LED on Airnet/Set Digital Outputs on ENODE Length: Approx. 87 bytes
Data Processing
The Ethernet instrument transmits data when the internally processed sample interval is complete. No polling for data is required.
Note: Particle counter sample points may utilize "Zero count sample interval" which will reduce traffic. ENODE digital input sample points are sent on change (exact conditions are setup in the instrument and in Facility and Pharmaceutical Net). ENODE Analog Inputs are all treated as separate sample points and each have their own sample interval.
Packet from Airnet/ENODE Messages: Data Length: Approx. 147 bytes Status & Date/Time Processing
Facility and Pharmaceutical Net requests status every two minutes from each Ethernet instrument. Facility and Pharmaceutical Net will add a date/time every thirty minutes to the status request packet.
Packet from Facility and Pharmaceutical Net Messages: Get Status Length: Approx. 87 bytes
Or
Packet from Facility and Pharmaceutical Net Messages: Date/Time, Get Status Length: Approx. 130 bytes
Packet from Airnet/ENODE Messages: Status Length: Approx. 115 bytes
Reproduction or translation of any part of this work without the permission of the copyright owner is unlawful. Requests for permission or further information should be addressed to Particle Measuring Systems, Inc. at 1-800-238-1801.